vs sup2t 10g datasheet. 1 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G xxx 2 48 CEF720 48 port 1000mb SFP WS-X6848-SFP xxx. vs sup2t 10g datasheet

 
1 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G xxx 2 48 CEF720 48 port 1000mb SFP WS-X6848-SFP xxxvs sup2t 10g datasheet  60

Looking for verification which one (or maybe both) is compatible so when we replace VS-SUP2T-10G with e. . 08-05-2012 07:57 PM. module 1: module 1 power-output-fail: OK module 1 outlet temperature: 66C module 1 inlet temperature: 51C module 1 asic-13 temperature: 79C module 1 asic-14 temperature: 81C module 1 EARL outlet temperature: 47C module 1 EARL inlet. 2(1)SY1 to build VSS is ok ? Or who can give me suggest version to build VSS. That's because although your OP asked about a 6708, your installed card in a 6908. Page 2 of 22 Contents IntroductionVS-S2T-10G= Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4-S-65-S720= WS-SUP720-3B w/512MB and 512PCMCIA. 部分Cisco. Cisco announces the end-of-sale and end-of life dates for the Cisco Catalyst 6500 Series Supervisor Engine 32, plus the Cisco Catalyst 6500 and Cisco 7600 Series Supervisor Engine 32 Bundles. module 7 asic-2 temperature: 47C. Switching Modules . Equipped with a high performance processor, the MSFC runs layer 2 protocols on one CPU and layer 3 protocols on the second CPU. Tray+Sup720-10G; IP Base ONLY incl. VS-C6509E-S720-10G Catalyst Chassis+Fan. This bypasses the need for a spare. VSS mode does not support 61xx switching modules. This document is Cisco Public Information. Product. Contact Service Express. 07. B. MSFC3. Im trying to understand the STP limitation of the Cat 6500 running Sup2T with IOS15. VS-S2T-10G. Before I configured VSS all modules working ok on both chassis, Below is show module output. I've done some digging where it seems to be the cards aren't supported by the VS-SUP2T-10G that is install. Having a problem bringing up 10GB ports between two Cisco 6509-E VS-SUP2T-10GB , they simply are not comming up Physically. The Supervisor engine 720 integrates a high-performance 720 Gbps crossbar switch fabric with a forwarding engine in a single module, delivering 40 Gbps of switching capacity per slot (enabling 4-port 10GE and 48-port 10/100/1000 density line cards). 12-27-2018 03:03 AM - edited ‎03-08-2019 04:54 PM. Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3C Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3CXL Cisco Catalyst 6500 Series Supervisor Engine 2T Power Supply Compatibility * Indicates EoS Power Supply AC: 2500W*, 3000W, 4000W, 6000W, 8700W DC: 2500W, 4000W, 6000W Module Compatibility All modules based on the software release in. module 7 asic-8 temperature: 70C. 7. Uplink ports (PORT 1 through PORT 5) ·Supervisor Engine 2T has five uplink ports: ·Two 10GBASE-X ports·Three 1000BASE-X ports·Each uplink port has a link LED associated with it. VS. 1(2)SY16—20 February 2020 • Release 15. With SUP720 and WS-X6716-10GE (DFC3) I. New here?Bias-Free Language. Be the first to write a review. Previous page. 56. remote login standby . Default Control Plane Policy on Catalyst 6500/Sup2T and Catalyst 6880 Configuration Example ;VS-S2T-10G= Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4 - S-65-S720= WS-SUP720-3B w/512MB and 512PCMCIA . . Configure the virtual switch links. That is correct. . Working in conjunction with the Catalyst ® Supervisor Engine 2T/2TXL. The new sup2t has been shipped to site, however, the failed sup has already been removed and sent back to Cisco so I dont have the old compact flash card, nor do I have a space chassis to pre-stage the replacement sup. 6 Tbps wired switching capacity, with 8 Bpps of forwarding performance is unleashed with Cisco Catalyst 9600 Series Supervisor Engine 2. module 5 asic-2 temperature: 37C. 150-1. 3 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1930KUZ5 5 24 CEF720 24 port 1000mb SFP WS-X6824-SFP SAL1930L1G8. The two supervisor engines must match exactly. Cisco IOS software commands display WS-X6708-10GE with either WS-F6700-DFC3C or WS-F6700-DFC3CXL. . Both switches need to run the same IOS version (check with 'sh ver'). I have this problem too. This modular switch stands for virtualization, highest availability, integrated security, best. This product is supported by Cisco, but is no longer being sold. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Cisco Catalyst 6500/6800 Supervisor 6T Architecture White Paper. As part of the upgrade the two chassis will be converted to VSS. Can you let me know if the following kit list will support the 6148 line card in VSS configuration - Cards and Modules 1. make sure you unplug the VSL links made the changes then connect them again also update the config in the primary VSS switch and save the config before joining them over. can we install new C6800-8P10G= Interface Module during switch power ON (during working condition), or. CSCto26539. All VS-SUP2T-10G have IOS: s2t54-ipservicesk9-mz. 375: %C6KENV-2-DFCMISMATCH: Module 2 DFC incompatible with Supervisor DFC. Doc Preview. (Sup VS-SUP2T-10G) Reviewed in the United States on 9 September 2012. 01:45. 2(50r)SYS3 . 1445. (Acti VS-SUP2T-10G SAL1618BM8W 2 16 CEF720 16 port 10GE WS-X6716-10GE SAL16159VEP 4 48 CEF720 48 port 10/100/1000mb Ethernet WS. EOS/EOL for 64MB Compact. The documentation set for this product strives to use bias-free language. The 6500 has only one supervisor engine so we will obviously need some downtime. Hi there VSS sups , you cant do seamless going to VSS from standard your going to take hits no matter what way , reason being theres a conversion section where it turns the switches into VSS capable , this causes a reboot , no way around it part ofEnd-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles & Accessories 17-Nov-2022. Cisco Catalyst 6500/6800 Supervisor 6T Architecture White Paper. 3 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G 4 5 Supervisor Engine 2T 10GE w/ CTS (CSSO VS-SUP2T-10G. you can run a show mod and you will see the serial numbers for the modules are different than the chassis. Cisco Catalyst 6500 4-Port 10 Gigabit Ethernet Fiber Module. MEM-SUP2T-2GB Catalyst 6500 2GB Memory for Sup2T and Sup2TXL. When I shutdown the chassis and install the SUP2T they never power up. bin. Because of hardware limitations and the method by which packets of different sizes are counted, the level percentage is an approximation. W/VS-F6K-PFC4 DAUGHTER CARD. 5 Ok 5 Distributed Forwarding Card WS-F6700-DFC3B SAL124592MR 4. To put it simple, is a card in the line card which provides certain most useful lookup functions. Catalyst 6500/Cisco 7600 Supervisor 720 Fabric MSFC3 PFC3B . 37 - - Switch 1 is using 2504. Verified Purchase. Could someone verify if the IDSM2 is compatibility with the Sup2T (running s2t54-ipservicesk9-mz. 94. The current switches have the same setup as per below: MUK_Core1#sh module. Either two VS-SUP2T-10G or two VS-SUP2T-10G-XL supervisor engines. Switching Modules. €5€€€ 5€ Supervisor Engine 2T 10GE w/ CTS (Active)VS-SUP2T-10G€ €€€€ SAL15056BKR Sup2T の場合、Eureka という内部コード名が設定されたレイヤ 2(L2)フォワーディング エン ジン(FE)で ELAM を実行します。L2 FE データ バス(DBUS)に、L2 およびレイヤ4 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1941QX54 5 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6848-GE-TX SAL1825UZLA. There's also a VS-SUP2T supervisor card. The initial cost will be high but you'll have more room for growth. I have two 6807 chassis with VSS architecture. A Bridge Connecting IT Hardware to The World Routers. bin. Bias-Free Language. Bias-Free Language. 3 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6848-GE-TX SAL19058UN3. Our super fast turnaround times and high quality stock located all. I recall, the only 67xx card that will not work with a sup2T is the 6708, because it comes with a DFC3 that cannot be replaced (with the DFC4 or a CFC). Le centre d’assistance technique de Cisco (TAC) continuera de prendre en charge les clients dont les contrats. Solved: Hi, We've just invested in a pair of Sup2Ts to upgrade a Sup720 6509 chassis but I'm unsure exactly how the management port (s), aka the Connectivity Management Processor (CMP), should be configured (and. Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) Humidity (RH) ambient (noncondensing) 10 to 90%. vs-s2t-10g=, there won't be any problem. 02-23-2016 12:48 AM - edited ‎03-08-2019 04:41 AM. C6880-16P10G. Would anyone be able to confirm that the below line card works with our T2 supervisors? The original ones WS-X6704-10GE= are end of life and can no longer be ordered. 5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1825UZQ4 Mod MAC addresses Hw Fw Sw Status 5 503d. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1. Dear All i wonder what are the features enabled to run in hardware on the VS-SUP2T-10G? Specifically i'm curious about "ip accounting mac-ad" command under the SVI. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500/6500-E Series 1 Gigabit Ethernet Fiber and Copper Line Cards and Accessories 31-Oct-2016. C6880-X-LE-SUP. 0. 2(1)SY1. This publication describes how to check the status of the voltage termination (VTT) modules and clock modules and describes how to remove and install the modules on the following Catalyst 6500 series switches and Cisco 7600 series routers: Catalyst 6500 Series Switches. 1 VS-S2T-10G Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4 21 days $ 28,000. Operating altitude. 879. VS-SUP2T-10G Catalyst 6500 Supervisor Engine 2T Baseboard VS-F6K-PFC4 Cat 6k 80G Sys Daughter Board Sup2T PFC4 MEM-SUP2T-2GB Catalyst 6500. In VSS mode, unsupported switching modules remain powered off. Find Cisco VS-S2T-10G-XL best price and specification, and more Cisco Catalyst 6500 Series Bundle: VS-S2T-10G-XL, delivering high speed and reliable network connections for you need. VSS mode does not support 61xx switching modules. Replacement. 00. 1 Ok. Is the following upgrade process correct? 1. 60. Hi, I have a VSS config with unequal number of switching modules as follows; Switch 1 ----- VS-SUP2T-10G (2x VSL) WS-X6704-10GE WS-X6748-GE-TX Switch 2 ----- VS-SUP2T-10G (2x VSL) WS-X6704-10GE Will VSS work if the WS-X6748-GE-TX isI need to upgrade a Cisco 6509 with dual SUP2T's ‏‏‎ from version 15. Cisco VS-S2T-10G Datasheet PDF Download the datasheet of Cisco VS-S2T-10G. Cisco OneX Converter Module5 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G SAL1731APXD 6 5 Supervisor Engine 2T 10GE w/ CTS (CSSO VS-SUP2T-10G SAL1731APZY 8 24 CEF720 24 port 1000mb SFP WS-X6824-SFP SAL1730AFG9. This chapter describes how to safely install, remove, and verify the operation of the Ethernet switching modules in the Catalyst 6800 series switches. 02. Recently got a 6504-E. 6 VS-SUP2T-10G supervisor CEF Router# This example shows how to display VLAN information: Router# show platform hardware capacity vlan VLANs: 4094 total, 10 VTP, 0 extended, 0 internal, 4084 free Router# Module Status Monitoring The supervisor engine polls the installed module s with Switch Communication Protocol (SCP) messages. Description. 10. Installing SUP2T in a 6807-XL chassis boosts backplane speed from 80 Gbps of an E-Chassis up to 220 Gbps, although this is nowhere near the chassis maximum capacity of 880 Gbps. Below is a comprehensive. TXO has the VS-SUP2T-10G in stock, along with a wide range of used and refurbished telecommunications equipment from all OEMs. 1 . Module Compatibility C6800-32P10G C6800-32P10G-XL C6800-16P10G C6800-16P10G-XL C6800-8P10G C6800-8P10G-XL. Note The 1-Gigabit Ethernet ports and the 10-Gigabit Ethernet ports have the same QoS port architecture (2q4t/1p3q4t) unless you disable the 1-Gigabit Ethernet ports with the platform qos 10g-only global configuration command. 5 VS-SUP2T-10G 435. 0004. we have purchased a new Nexus 9K and we need to connect it to our core switch 6513 with 2 supervisor engines "VS-SUP2T-10G 5 ports . . Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4 - WS-SUP720-3B . the online version 15. Search for:. Cisco 7606S Chassis,6-slot, Red System,VS-S2T-10G-XL,2PS. Cisco Nexus 7000 4-Slot Switch Chassis. EOS/EOL for 64MB Compact Flash for Cisco Catalyst 6500 Supervisor Engine 720/32 27-Jul-2017. Our super fast turnaround times and high quality stock located all. Sup2T の場合、Eureka という内部コード名が設定されたレイヤ 2(L2)フォワーディング エンジン(FE)で ELAM を実行します。L2 FE データ バス. pdf - F4F1AS6152AC07B. 4 Ok 7 Distributed Forwarding Card WS-F6K-DFC4-A SAL1927JC3V. Hi, We are trying to upgrade our 6807 VSS switches to 15. We have VS-SUP2T-10G for sale, both refurbished and new, at prices typically up to 90% less than the original vendor price. . Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4. Catalyst 9600 Chassis and Line Cards with C9600X-SUP-2. WS-X6816-10G-2T: 16-port 10 Gigabit Ethernet Fiber Module with DFC4 (Figure 1) and WS-X6816-10G-2TXL: 16-port 10 Gigabit Ethernet Fiber Module DFC4XL (Figure 1) Backplane connection: Connects to the switch fabric using dual full-duplex 20 Gbps switch fabric channels (40 Gbps total). WS-SUP720 Supervisor Engine 720 with PFC3A daughter card and integrated MSFC3 and switch fabric. Feature VS-S2T-10G VS-S2T-10G-XL Port security Yes Yes IEEE 802. The Future Is 40 Gigabit Ethernet White Paper (PDF - 2 MB) Virtual Private LAN Service on Cisco Catalyst 6500 Supervisor Engine 2T. 16 Tbps of bandwidth and 1. 46W from both 6000W supplies, and if one of the them fails, it will still use 2504. Both switches used Supervisor Engine 2T 10GE , VS-SUP2T-10G 5 ports as follows: C6509-E sho module Mod Ports Card Type Model --- ----- ----- ----- 1 486 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL17163A4C 8 40 DCEF2T 8 port 40GE / 32 port 10GE C6800-32P10G SAL2120011E Mod MAC addresses Hw Fw Sw Status. Catalyst Chassis+Fan Tray+Sup720-10G; IP Base ONLY incl. 15. 0 Helpful Reply. Router# show platform hardware capacity system System Resources PFC operating mode: PFC4 Supervisor redundancy mode: administratively sso, operationally sso Switching resources: Module Part number Series CEF mode 6 VS-SUP2T-10G supervisor CEF Router# This example shows how to display VLAN information: Platform scalability: Delivering up to 80 Gbps per slot of switching capacity on E-Series chassis; 2-Terabit aggregate bandwidth capacity using the 6513-E chassis, scaling to 4-Terabit capacity with. Additionally, customers have the option to migrate to the Supervisor Engine 720-10G-3C, which supports Virtual Switching System (VSS). Cisco announces the end-of-sale and end-of-life dates for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS. 1200 ports scale support on Sup2T —See this publication:vs-c6509e-sup2t-rf Cat ChassisFanTray+Sup2T;IP SvcsONLY incl VSS REMANUFACTURED. Hall of Fame Guru Options. Manufactured by Cisco. 1 Accepted Solution. Thanks for your comment! Hi I'm confused about what is the best procedure to replace a failed SUP2T-10G on VSS because I founded 2 ways: 1° - Replace the failed SUP -Copy the Same IOS on the new SUP -Configure the VSS: switch virtual domain 100 switch 1 priority 200 !Hi experts, I have two 6500 in VSS. 0 (2)EX2 is connected to VSS on WS-X6904-40G linecards with a. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Sup Engine is not able to sync each other and standby Sup restart when the active Sup is detach. Beginner. 0ffd. module 7 RP outlet temperature: 43C. 1. Is this correct? Switch 2 is also consuming the same amount of power like Switch 1 due to the same modules, but. We have VS-SUP2T-10G for sale, both refurbished and new, at prices typically up to 90% less than the original vendor price. Aruba 8320 48p 10G SFP/SFP⁠+ and 6p 40G QSFP⁠+ Switch. VS-S2T-10G-XL Supervisor Engine 2T-10GE with PFC4XL. A faster CPU and expanded memory compared to the first-generation. (s2t54-ADVIPSERVICESK9-M), Version 15. Note that the L2 FE Data Bus (DBUS) contains original header information before the L2 and Layer 3 (L3) lookups, and the Result Bus (RBUS). Cisco Catalyst 6500系列Supervisor Engine 2、交换矩阵模块2 以及部分附件和软件版本终止销售 (EOS)和产品生命期终止 (EOL)声明 26-Aug-2016. It provides up to 34 10 Gigabit Ethernet ports in a single Cisco Catalyst 6509 chassis and 68 10 Gigabit Ethernet ports in a VSS. 03-27-2012 01:46 AM - edited ‎03-07-2019 05:48 AM. However this card seems not to be supported by the SUP2T-10G supervisor. EOS/EOL for 64MB Compact Flash for Cisco Catalyst 6500. Which alternative card should I take for this EOL linecard, or can I use the proposed linecard (use extra daughtercard DFC4)?Symptom: Cat6500 %LICENSE-6-RECOVERED message output when reload device. Depending on the sizes of the frames making up the incoming traffic, the actual enforced level might differ from the configured. Mod Sub-Module Model Hw. The images may differ slightly from the original and are used for illustration. No. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories. BTW, Reza mentions the sup and DFC XL feature needs to match, i. 7 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G SAL202801YG. K. Cat 6500 Supervisor 720 with 2 ports 10GbE MSFC3 PFC3C --Sweta *Rate and mark the helpful answers. When your line card has the DFC4-A installed IT. VS-S2T-10G | The Cisco Catalyst 6500 Series is the flagship among switching platforms. Canon Perdido, Suite 100 Santa Barbara, CA 93101Same bug for VS-SUP2T-10G on Cisco 6807XL VSS version 15. The Cisco® Catalyst® 6500 Supervisor Engine 2T is the newest addition to the family of supervisor engines. Attache. Customers are encouraged to migrate to the Cisco Catalyst 6500 Series Supervisor Engine 2T for the latest technology innovation, scalability, and performance enhancements. Each Chassis has two VS-SUP2T-10Gs. Bias-Free Language. The current switches have the same setup as per below: MUK_Core1#sh module. e514. 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles and accessories Milestone Definition Date End-of-Life Announcement Date The date the document that announces the end-of-sale and end-of-life of a product is distributed to the general public. 46W from on 6000W power supply. The Supervisor Engine 6T is designed to deliver higher performance, better scalability, and enhanced hardware-enabled features. The ports are Gi1/5/3 and Gi2/5/3. . 5cd9. 4 points of motion control On/Off signal can be selected by 1 switch ; Max. All forum topics; Previous Topic; Next Topic; 7 Replies 7. 2. EOS/EOL for 64MB Compact Flash for Cisco Catalyst 6500 Supervisor Engine 720/32. Options. 15. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories 03-Aug-2020. 1 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G . 0 Ok 5 Distributed Forwarding Card WS-F6K-DFC4-A SAL1825UZLA 1. Open box. Catalyst 6500 10 Gigabit Ethernet For Sup2T WS-X6908-10G-2T-RF The Cisco Catalyst 6900 Series 8-port 10 Gigabit Ethernet Fiber Module is the first 10 Gigabit Ethernet module that supports Cisco TrustSec and layer 2 encryption in hardware to enable IEEE 802. Hey All I have a failed sup2t (VS-SUP2T-10G) in a quad supervisor deployment. $38000. Download the datasheet of Cisco VS-S2T-10G-XL. 30 points of limit switches output; Max. Each switch only has one Supervisor module (VS-SUP2T-10G). 7Tbps. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles & Accessories. what is the IOS code running, Try below syntax : logging origin-id string <device_hostname>. Only WS-X6904-40G-2T is being replaced and not the C6800-32P10G module. 442 12748176 4456882 2860 33. Although not mandatory, we recommend that you install a second 2-GB DRAM module when installing VS-F6K-PFC4XL=. Only a single chassis VSS with single or dual Supervisors is supported. As the 1G and 2 x 10G ports share the total 20G bandwidth points on the SUP2T, if both 10G ports are used for VSL, the 1G ports can not. C6880-X-LE-16P10G. Cisco Nexus 7000 Series Supervisor2 Module. Mod Online Diag Status---- -----1 Pass 2 Pass 3 Pass. This document describes the supervisor replacement procedure for Cisco Catalyst 6500 Series switches that run in Virtual Switching System (VSS) mode with Quad-Sup720 or Quad-Sup2T. 5(1)SY2, page 52 † New Features in Release 15. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Sup Engine is not able to sync each other and standby Sup restart when the active Sup is detach. module 7 device-2 temperature: 41C. Again, not very familiar with the sup2T, but on a 720 you can specify just a device as part of the boot string, and the boot process will look for any valid image (I believe restricted to the root of the device) and boot it. 2+ VSS mode support as shown in the Release Notes. The modules also work in Catalyst 6500 Series Switches. 67. Working in conjunction with the Catalyst® Supervisor Engine 2T/2TXL (VS-S2T-10G & VS-S2T-10GXL) or Catalyst Supervisor Engine 6T/6TXL (C6800-SUP6T & C6800-SUP6T-XL), they can serve different needs on campus deployments. 04-16-2017 08:35 AM. The answer, I believe, is yes. 1x extensions Yes Yes VLAN and router ACLs and port ACLs Yes Yes 1:1 mask ratio to ACE values Yes Yes Security ACL entries 64K shared for QOS / Security 256K shared for QOS/Security CPU rate limiters (DoS protection) 57 57 To upgrade from VS-S2T-10G to VS-S2T-10G-XL, remove VS-F6K-PFC4= from the corresponding supervisor engine and install VS-F6K-PFC4XL=. Service prices for Cisco products are subject to change after the product End-of-Sale date. Power deniedPart Number Description 2 VS-S2T-10G= Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE withMSFC5 PFC4 2 S2TAIK9-15501SY Cisco CAT6000-VS-S2T IOS ADVANCED IP SERVICES FULL ENCRYPT 2 MEM-SUP2T-4GB 4G DRAM Memory Total for Sup2T and Sup2TXL (2G + 2G) - UPGR 2 MEM-C6K-CPTFL2GB Catalyst 6500 Compact Flash. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles & Accessories 17-Nov-2022. s2t54-advipservicesk9-mz. Is the following upgrade process correct? 1. 2 OkVS-SUP2T-10G が稼動する Catalyst 6500 シリーズスイッチではライセンスのインストールは必要ありませんが、同様な実装の他の機器と異なり、以下の様に、'show license' コマンドが入力でき出力も表示されます。 この動作は不具合ではありませんので、出力等に関して調査を行う必要はありません。5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL17194J7J. 1x and 802. 0 (1)SY1. hello, i have ordered VS-S2T-10G-XL but when i am doing a show invetory it is showing it as VS-SUP2T-10G. 2 (50r)SYS2. Solved! Go to Solution. 1a18 to 1cdf. . 1. 11-26-2018 09:12 AM. Beginner Options. VS-SUP2T-10G Catalyst 6500 Supervisor Engine 2T Baseboard. 66. WS-X6708-10G-3C and WS-X6708-10G-3CXL are the orderable product IDs. A single 6800IA that runs Cisco IOS software Release 15. 00BOM. 0021 2. CSE. VS-SUP2T-10G-PFC4XL Supervisor Engine 2T with PFC4XL daughter card. Cisco announced some new modules for Cat6500 last month. 86 120. This card can be acquired and installed by yourself with no problems. 2 Release Notes for Cisco IOS Release 15. The Cisco® Catalyst® 6500 Supervisor Engine 2T is the newest addition to the family of supervisor engines. I need to enable QoS on these switches, primarily to trust dscp and also to prioritise voice traffic. Working in conjunction with the Catalyst ® 6500-E/6807-XL Supervisor Engine 2T/2TXL (VS-S2T-10G & VS-S2T-10GXL), they can serve different needs on. e514. With VSS, both supervisor engines must be the same. We only have VS-SUP2T-10G and C6800-32P10 in our VSS. I checked the supervisor and supports both tranceivers, but I want to know if I can have one of each instead of 2 of the same kind on the same supervisor. ! And then I found that VS-SUP2T-10G's Factory ID was VS-S2T-10G! But I don't know the difference between them. ChiefTeam538. CISCO VS-S2T-10G, VS-SUP2T-10G,CMUCAB3BAA SUPERVISOR 2T WITH INTEGRATED SWITCH FABRIC/PFC4 AND 2 PORTS 10GBE. You can also save your config to a tftp server and. VSS VS-C6509VE-SUP2T Catalyst Chassis+Fan Tray + Sup2T; IP Services ONLY incl VSS Upon LDoS of the Bundle PIDs, customers have the option to book Service Contracts on the individual components of the Bundle, based on components support availability. 2 8 DCEF2T 8 port 10GE WS-X6908-10G SAL1643QYRY. VS-SUP-2T-10G. 2GB for Lite and XL (4GB upgrade with 2GB memory upgrade (2+2) NVRAM. K. Cisco Catalyst 6500系列Supervisor Engine 2、交换矩阵模块2 以及部分附件和软件版本终止销售 (EOS)和产品生命期终止 (EOL)声明 26-Aug-2016. 4/12/2018 Cisco Catalyst 6500 Series Supervisor Engine 2T Data Sheet - Cisco 3/14 Name VS-S2T-10G VS-S2T-10G-XL NAT Hardware assisted Hardware assisted MAC entries 128k 128k. 36 A; VS-S2T-10G-XL—10. Upload IOS File to bootdisk: #copy tftp: bootdisk: #copy bootdisk: sw1-slot4-bootdisk: #copy bootdisk: slavebootdisk: #copy bootdisk: sw2-slot4-bootdisk: 2. 41 x 1. They include a 48-port Gigabit Ethernet Copper Module and 48-port Gigabit Ethernet Fiber Module. I installed Sup2T engine on 7606-x chassis. VS-S720-10G: Cat 6500 Supervisor 720 with 2 x 10GbE. All rights reserved. Free PDF of Cisco VS-S2T-10G. Catalyst Chassis+Fan Tray + Sup2T; IP Services ONLY incl VSS- 0 Helpful. 0 Ok 6 CPU Daughterboard VS-F6K-MSFC5 SAL202900EV 3. Cat6k - Sup2T - DHCPv6 control packets snooped by MLD when forwarded over VPLS circuit. Before you replace the old sup, make sure you have a good copy of the config. 33 161. I use the module together with X2 To Sfp+ Adaptor. 6 Tbps in wired switching capacity, with up to 6. A Bridge Connecting IT Hardware to The World Routers Switches Firewalls Wireless Servers Storages Solutions Services About Us ×. VS-C6513E-SUP2T. And Cisco proposed the 2 substitutes written above: vs-s2t-10g= and vs-s2t-10g-xl=. Explore our database of over. All forum topics; Previous Topic; Next Topic; 2 Replies 2. Each Chassis has two VS-SUP2T-10Gs. Greetings, I do not know if this is already a thread in the forum, but I have been searching for it and did not find it. module 7 asic-2 temperature: 47C. can we install new C6800-8P10G= Interface Module during switch power ON (during working condition), or is it require a downtime. 37 435. Hi All, I am currently looking at a VSS solution, which requires PoE line cards. SPA. $88,000. 1ae (MACSec) encryption for Role-Based Access Control (RBACL) functionality. e. Options. Compact Flash. Table 2 Supervisor Engine 2T Models; Supervisor Engine 2T Product Numbers Description VS-S2T-10G The VS-S2T-10G is shipped with a factory-installed PFC4 daughter card (VS-F6K-PFC4) and a factory-installed MSFC5 daughter card (VS-F6K-MSFC5). 5050 or Request a Quote online. 1ms of signal updating cycleHigh-density fiber line cards for campus core and distribution. module 7 device-1 temperature: 40C. Cat 6500 Supervisor 720 with 2 x 10GbE and 3x1GE MSFC3 PFC3C - WS-SUP720-3B= Catalyst 6500/Cisco 7600 Supervisor 720 Fabric MSFC3 PFC3B . In VSS mode, unsupported switching modules remain powered off. 00 66% OFF. VS-S720-10G-3C= Cat 6500 Supervisor 720 with 2 x 10GbE and 3x1GE MSFC3 PFC3C-VS-C6513-S720-10G. The two supervisor engines must match exactly. 1x extensions Yes Yes VLAN and router ACLs and port ACLs Yes Yes 1:1 mask ratio to ACE values Yes Yes Security ACL entries 64K shared for QOS/Security 256K shared for QOS/Security CPU rate limiters (DoS protection) 57 57 uRPF check (IPv4/IPv6) Up to 16 Up to 16 これらのモジュールを Cisco Catalyst 6500-E/6807-XL Supervisor Engine 2T/2TXL(VS-S2T-10G および VS-S2T-10GXL)と連携させれば、キャンパス環境のさまざまなニーズに対応することができます。. 1 VS-S2T-10G Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4 21 days $ 28,000. item 5 NEW SEALED CISCO VS-S2T-10G-XL - Sup2T, 2x10GbE, 3x1GbE - LIFETIME WARRANTY NEW SEALED CISCO VS-S2T-10G-XL - Sup2T, 2x10GbE, 3x1GbE - LIFETIME WARRANTY.